Navigation
Description

Product Description

FM or AM processing on demand is standard. Simultaneous FM+AM if programming is 100% simulcast and at same transmitter site. Studio output with very low latency for talent monitoring is also standard. Optional HD-1, HD-2, HD-3 processing and streaming/encoding, RDS. Dual path model available for two separate program feeds broadcasting on FM+FM, FM+AM or FM+FM+AM simulcast with HD output, IP-Streaming with separate processing and encoding and low latency studio processing, all built-in for both feeds.

Please follow and like us:
More Info

Additional Information

Frequency Response

+/-0.5dB 20Hz to 15kHz, 17.5kHz in extended mode

Signal to Noise Ratio

Greater than -80dBu de-emphasized, 20Hz to 15kHz

System Distortion

Less than 0.01% THD below pre-emphasis, inaudible above

Stereo Separation

65dB minimum, 20Hz to 15kHz, 70dB typical

Digital Output Level

Adjustable from -24.0dBFS to 0.0dBFS in 0.1dB increments

Stereo Baseband Output

Adjustable from -2dBU to +22dBU (0.1dB increments) into 600-Ohms, 20-Ohm output impedance

A/D Conversion

Crystal Semiconductor CS5361, 24 bit 128x over-sampled delta sigma converter with linear-phase anti-aliasing filter.
Pre-ADC anti-alias filter, with high-pass filter at <10 Hz

D/A Conversion

Crystal Semiconductor CS4391, 24-bit, 128x oversampled

External Sync Input

Per AES11 Digital Audio Reference Signal (DARS), reference for digital output sample rate. Range is 32kHz to 96kHz.

Analog I/O

Two balanced, EMI filtered XLR connectors

Stereo Generator Connections

Four 75-Ohm BNC female, two inputs, two outputs
(FM style only) AES/EBU In & External Sync

Digital I/O

AES/EBU via four XLR connectors for Main and Aux Digital programs (two stereo in, two stereo out)

Ethernet

Shared RJ45 supporting 100 and 1000BASE-T Ethernet connections

Power Requirements

100-264 VAC, 47-63Hz autosensing, dual PSU

Power Connector

Dual IEC male, detachable 3-wire power cords supplied

Power Supply

Internal dual redundant, hot-swappable

Environmental

Operating: 0 to 50 degrees C
Non-operating: –20 to 70 degrees C.

Back to top